External Installation #
Measure Case & Mount L Brackets #
Mount the L brackets either to a vertical or horizontal structural support as shown. Make sure brackets are all along the same level line and plumb.
Mounting screws have been provided for mounting to wood structural supports only. If mounting to other substrate then installer must provide appropriate fasteners.
Warning: Each bracket must be able to hold 200lb load.
Remove Weight Bar Lock, Hang Case and Raise Up #
Make sure the hooks on the L brackets are adjusted down. Then raise the case up and hook the case into all hooks on each bracket.
Tighten the screws in the brackets until the case firmly presses against the L brackets and ensure the cassette is level.
External Trim & Fascia #
Fascia Install & Fascia Lock #
Hook the trim into the case opposite the weight bar and then rotate down to secure. Make sure the trim is hooked into the case along entire length before proceeding.
Hook the fascia onto the front of the case as shown.
Use the 9/64″ hex key to loosen the two screws securing the fascia lock. Then slide the lock down to lock the fascia in place. Finally secure the fascia lock by hand tightening the two screws securing the fascia lock position. Do this on both ends of the case.
Remove the tagged Weight Bar Locks.
Adjusting Tab Tension #
Loosen tension: Press in the button and turn knob counter clockwise until the string is loose.
Apply minimal tension: Turn the knob clockwise 2 to 4 clicks at a time until there is tension on the string. The strings should have minimal tension on them only.
Warning: DO NOT OVER TIGHTEN TAB TENSION STRINGS: Tab tension strings will NOT flatten out wrinkles in the screen. The purpose of tab tensioning is to reduce viewing material edge curl. Over tightening the tab tension strings can result in damage to your screen material.
Line Level Voltage (AC) – Wiring #
Terminate the wires with the provided terminal block shown below.
Make sure an appropriate junction box or power receptacle is located within 5ft of the installation location.
Warning: Installer must follow all local electrical codes when connecting 110v AC power. Certified electrician is required to connect pigtail power.
110v AC/60 Hz: L (Black), N (White), Ground (Green) — Length: 12-14′
220v AC/50 Hz: L (Brown), N (Blue), Ground (Green/Yellow) — Length: 8’4″
110v AC – DCT Motor #
Low Voltage (DC) – Wiring #
DC Motor Wiring:
Power 24v DC – Red
Ground – Brown
RS485 (+) – White
RS485 (-) – Orange
Pin 1 to Pin 8 (with service loop)